Net-Radiometer
Net Radiometer - CNR4
The CNR4 net radiometer measures the energy balance between incoming short-wave and long-wave Far Infrared (FIR) radiation versus surface-reflected short-wave and outgoing long-wave radiation.
The CNR4 net radiometer consists of a pyranometer pair, one facing upward, the other facing downward, and a pyrgeometer pair in a similar configuration. The pyranometer pair measures the short-wave radiation. And the pyrgeometer pair measures long-wave radiation. The upper long-wave detector of CNR4 has a meniscus dome. This ensures that water droplets role off easily and improves the field of view to nearly 180°, compared with a 150° for a flat window. All 4 sensors are integrated directly into the instrument body, instead of separate modules mounted onto the housing. But are each calibrated individually for optimal accuracy.
Two temperature sensors, a Pt-100 and Thermistor, are integrated for compatibility with every data logger. The temperature sensor is used to provide information to correct the infrared readings for the temperature of the instrument housing. Care has been taken to place the long-wave sensors close to each other and close to the temperature sensors. This assures that the temperatures of the measurement surfaces are the same and accurately known. Which improves the quality of the long-wave measurements.
The design is very light in weight and has an integrated sun shield that reduces thermal effects on both long-wave and short-wave measurements. The cables are yellow with waterproof connectors as used with all our new radiometers. The mounting rod can be unscrewed for transport.
An optional CNF4 ventilation unit with heater is designed as an extension of the sunshield and can be fitted new to the CNR4 or retro-fitted later. This unit is compact and provides efficient air-flow over the domes and windows to minimize the formation of dew and reduce the frequency of cleaning. The integrated heater can be used to melt frost.
Net Radiometer - NR Lite2
NR Lite2 is designed for routine measurement of net radiation which is the balance between incoming and outgoing radiation under outdoor conditions.
The design of the NR Lite2 is unique. The double-sided detector has black conical absorbers with an anti-stick weather resistant protective coating. In contrast to other sensor designs, NR Lite2 requires no fragile plastic domes. This results in a virtually maintenance free design. The vertical stick prevents birds from affecting the output signal.
The NR Lite2 is easy to use. It is based on a thermopile sensor. The voltage is proportional to the net radiation. It can be directly connected to voltmeter or data logger with an mV input. It has the same high quality yellow cable fitted as our other instruments.
The NR Lite2 is suitable for outdoor use conditions and fully complies with CE regulations
Net Radiometer - SN-500-SS
Apogee Instruments’ new four-component net radiometer provides individual measurement of net radiation components. The sensor features an SDI-12 output, eliminating the need for multiple analog channels to measure the individual components of net radiation. The net radiometer comes as a complete package that includes net radiometer, mounting rod, pigtail lead cable for datalogger interface, and carrying case.
Onboard A/D Conversion and SDI-12 Output
Apogee net radiometers feature onboard A/D conversion and SDI-12 output to eliminate the requirement of multiple analog datalogger channels.
Four-component Net Radiometer
An upward-looking and downward-looking pyranometer, and an upward-looking and downward-looking pyrgeometer provide separate measurements of the four components of net radiation.
Individually Heated Radiometers
Each radiometer includes an individual heater to increase accuracy by minimizing the influence of dew/frost on the filter.
Compact and Light Weight
Designed to be light weight and small in size to facilitate easy mounting.